施组设计下载简介:
内容预览随机截取了部分,仅供参考,下载文档齐全完整
工程施工组织设计及施工总结工程施工组织设计及施工总结
第一章 编制说明·················································································1
1、工程概况··················································································5
2、建筑设计特点··········································································5
GB/T 41899-2022标准下载3、结构特点··················································································8
4、设备··························································································9
5、本工程施工特点······································································10
6、地点特征··················································································11
7、施工条件··················································································12
8、对建设单位要求······································································12
9、主要工程量··············································································13
10、工程总价················································································13
11、总耗工····················································································13
12、主要材料用量········································································13
1、施工阶段划分··········································································14
2、施工分段与主体交叉平行流水作业·······································14
3、分部、分项施工方法·······························································16
4、各专业分工··············································································20
5、各项指标控制要求···································································20
6、采用新工艺、新技术、新材料···············································21
7、与建设单位和监理单位的配合···············································23第四章施工部署·················································································27第五章施工方法
(一)地下室施工········································································35
1、测量放线定位··········································································35
2、土方工程··················································································36
3、降排水······················································································36
4、混凝土钻孔灌注桩···································································37
5、裙房基坑探墓··········································································44
6、灰土及砼垫层施工···································································45
7、余桩头处理··············································································45
8、铺贴高分子防水卷材·······························································46
9、花铺200g沥青油毡·································································46
10、细石砼保护层········································································46
11、钢筋工程·················································································46
12、模板工程················································································50
13、混凝土工程············································································62
14、地下室外墙防水及保护层施工·············································68
15、后浇带施工············································································69
16、汽车坡道施工········································································71
17、地下室外墙回填土·································································71
18、地下水池施工········································································72
19、垂直与水平运输·····································································72
(二)地面上主体结构·································································72
1、测量放线··················································································72
2、钢筋工程··················································································75
3、模板工程··················································································79
4、混凝土工程··············································································84
5、砌体工程··················································································91
(三)外墙内侧ASA板安装·······················································95
(四)门、窗工程········································································97
(五)屋面工程·············································································102
(六)装饰工程·············································································104
(七)脚手架·················································································107
(八)垂直运输·············································································117第六章施工预算·················································································120第七章施工进度阶段计划及施工层进度计划··································121第八章主要资源需用量计划·····························································122第九章施工准备工作与实施计划······················································124第十章施工现场平面布置·································································125第十一章质量保证措施···································································128第十二章工期保证措施···································································136
第十三章施工技术措施···································································139
第十四章降低成本措施·····································································145第十五章成品保护措施·····································································147第十六章季节性施工措施·································································150第十七章安全施工措施·····································································155第十八章文明施工措施·····································································157第十九章施工组织及施工进度计划··················································171第二十章工程总包管理·····································································180第二十一章工程交付、服务及保修··················································204第二十二章施工技术资料管理··························································207
1、安装工程概况···················································································1
2、安装工程设计特点···········································································1
3、安装工程施工工艺···········································································3
4、主要施工方法、技术措施及技术质量要求····································6
5、建筑、电气安装工程施工方法、技术措施及技术质量要求·········13
6、系统安装、试验、检测和调试运行················································16
7、火灾报警系统调试···········································································18
8、设备的试运行···················································································19
9、施工中与土建的衔接·······································································19
10、安装过程中的成品保护··································································20
11、安装工程执行的施工及验收规范··················································21
12、安装工程管理组织机构··································································22
13、安装工程主要计量器具配备一览表··············································23
14、安装工程主要机械一览表······························································24
1、**大厦D座工程施工平面布置图
2、项目经理及项目管理人员业绩一览表
3、主要劳动力需要量计划表
4、主要材料需用量计划表
5、通迅、监控、质量检测计量器具计划表
6、施工周转材料计划表
7、机械设备需用及投入量计划表
8、主要机械设备用电负荷情况一览表
9、±0.000以下结构层施工进度计划表
11、标准层结构层施工进度计划表
12、悬挑转平台结构图
13、施工进度计划横道图
14、施工网络计划控制图
1、作用:施工组织设计是规划和指导本工程从施工准备到竣工验收全过程的综合性的技术经济文件,是沟通工程设计和施工之间的桥梁。它既要体现拟建工程的设计和使用要求,又要符合本工程的客观规律,对施工的全过程起战略部署或战术安排作用。施工组织设计是对施工准备工作的重要组成部分,也是做好施工准备工作的主要依据和重要保证。
施工组织设计是对施工过程实行科学管理的重要手段,是编制施工进度计划和施工预算的主要依据,是本工程施工管理的重要组成部分,据此,编好施工组织设计可以达到科学的规律组织施工,建立正常的施工程序、有计划地开展各项施工,及时做好各项施工准备工作,保证劳动力和各种资源的供应和使用;可以协调好各施工单位、各工种资源之间以及空间布置与时间安排之间的关系,可以保证施工顺利,进行按期按质量完成施工任务,取得更好的施工经济效益等,都将起到重要的积极作用。
2、本工程施工组织设计是在土方和工程结构钢筋混凝土钻孔灌注桩等分项工程,由建设单位分包给各兄弟单位完成的前提下进行编制的。编写包括地下室和地面主体结构、内外装修、屋面工程、室外工程、设备安装等分项工程,但不包括电梯和水泵采购、安装以及高低压盘及变压器的采购安装,中央空调系统及设备的采购与安装、消防自动报警及
控制系统的采购与安装,铝合金门窗的采购及安装(由招标文件已约定)。
3、分部分项工程的主要施工方法,按设计单位提供的施工图,认真严格贯彻与执行国家施工规范、规程及陕西省有关地方规程及有关规定,加之甲乙双方商定的技术要求施工:设计变更通知,应由发包方委托监理和设计单位签证后,方可组织施工。
4、先进的施工技术是提高劳动生产率,改善工程质量,加快施工进度,降低工程成本的主要途径,在选择施工方案时,本工程应根据实际情况,积极采用合理化建议、新材料、新设备、新工艺和新技术。在具体落实施工时,必须符合国家施工验收规范,技术规范、技术规程、施工方法的要求和遵守有关防火、安全及环卫等方面的西安市建设工程质量安全监督站文件:市建质[2000]30号文,以及市建委[1997]048号文件
《关于开展创建文明工地的决定》,确保工程质量和安全生产的前提下,加快施工进度,达到优质高速、高效益、低消耗的目的。为此,在施工全过程中,本着需要和可能的原则,有必要对施工方案进行调整、补充、完善,具体体现在技术核定单和技术交底。
(1)招标文件(包括投标的标书),与主管部门对本工程的批示文件。
(2)2004年9月27日答疑纪要。
(3)西安市建筑设计研究设计的经过会审的建筑施工图及工程地质
(4)现行的国有施工验收规范、规程、技术规范、质量标准及有关施工方法,陕西省的地方规定。
(5)本工程的设计预算和施工预算文件。
(6)建设单位工程施工可能提供的条件(包括招标文件中规定的)。
(7)本工程的施工条件,配备的技术行政管理力量、配备的劳动力、材料、施工机具以及生产能力。
(8)各有关工具书A:同济大学出版的“高层建筑施工手册”B:“高层建筑结构工程施工”同济大学赵志缙、赵帆编著。C:中国建筑工业出版社的“建筑施工手册”、“大体积混凝土施工”、
“装饰工程施工手册”、“新型建筑材料实用手册”、“建筑业102项新技术及其应用”、“建筑工程模板施工手册”、“钢筋工程手册”、“建筑施工新技术工艺卡”、“建筑工法与实例”、“建筑工程施工组织设计编制手册”、“建筑新技术操作手册”、“建筑施工工艺标准”、“混凝土工程新技术”、山东省科学技术出版社的“建筑施工新技术”、“建筑施工计算手册”、“高层建筑混凝土结构技术规程”、“建筑分项工程施工工艺标准”。
共计168天,局部机房和水箱层及砼网架共计为20天,合计为298天,
其中穿插地下室外墙防水内装修工程(砌填充墙、外墙内保温、内墙和顶棚粉底灰,厨、卫间防水、内墙面贴面砖、地下室内装修、设备预留预埋和安装等等),春节放假40天。
8、本工程,主楼在主体结构施工时,进行平行流水作业,裙楼待主楼主体完成至0.000M后基坑进行开挖和主楼施工形成交叉流水作业。
9、工程质量目标:确保省优质工程。
10、安全生产目标:无伤亡事故,确保省级文明工地。(在工程进度未到±0.000之前,先行去西安市建委有关部门办理申请手续。)
**大厦D座楼,位于西安市北**区**路**号,“西安**石油管道公司”
****建设工程总承包有限公司所属西安分公司,进行参加竞标,根据西安**房地产开发有限责任公司2004年9月11日下发的招标文件,依据文件要求:计划开工日期为二OO四年十一月十日,竣工日期为二OO六年八月十日。总工期为630个日历天。根据建设单位要求:本工程的质量等级为合格,施工单位的工程质量目标:确保省优质工程。为此,根据国家有关施工与技术规范与规程及陕西地方有关规定、精心组织施工,达到高质量、高速度、高效益、低消耗,按时交付使用。
2、建筑设计特点:本工程为一个单位工程组成,地下室为一层:层高为3.60m,管沟层
宽为32.90m。本工程主楼、裙楼电梯均为3座,其中1座为消防电梯,另设一消防楼梯一座(由地下室直通28层顶)。
(1)楼地面:楼面一层1:6水泥炉渣垫层上,现浇100mm厚钢筋混凝土板(地沟盖板另预制),其面层和卫生间前室及走道坎为地砖面层,楼梯间电梯机房为水泥面层,水箱间为随捣随光细石混凝土面。
(2)踢脚:楼梯间、地下室全部、电梯机房、水箱间为水泥砂浆。门厅前室及走道为花岗岩板。
(3)内墙面:地下室全部、空调、水泵、电梯机房、水箱间为水泥砂浆面层。卫生间、厨房为面砖面层,其他部位为纸筋(麻刀)灰墙面涂料面层,但住宅户内不做,面层由房主自定。
(4)住宅和办公部分外墙在200厚非承重空心砖墙和钢筋砼板墙内侧,均贴ASA板,住宅和办公部分与楼梯间、电梯井道、管道井、公共走道之间的隔墙,靠住宅办公一侧均抹30厚MD保温砂浆。
(5)顶棚:人防地下室、板底刮腻子、刷乳胶漆、卫生间、厨房、PVC条板吊
顶,空调水泵、直燃机房矿棉吸声板吊顶,其他房间为涂料面层(住户门内不做面层)。
地下室:室内隔墙采用MU10标准砖,M5.0水泥砂浆砌筑±0.000m
以上采用KF18非承重大孔空心砖M7.5混合砂浆砌筑(外墙及分户墙)。
厨房、卫生间内外剪力墙间填充墙采用粘土空心砖,M5.0混合砂浆砌筑。
(7)门窗:有防护密闭门、密闭窗、防爆活门、三防门,对讲防盗门、木门、
铝合金门窗、防火门。外装修:
油漆:木材面为奶油色调和漆,金属设备为白色瓷漆,其他金属面为白色调和漆。
室外踏步和平台为花岗岩面层。
±0.000标高,相当于绝对标高为390.95m,室内外高差为0.5m。屋面:19.50M、93.20M标高处为上人屋面,铺地砖面层。23.10M、
101.20M标高处为不上人屋面,卷材为自带保护层屋面,保温为120厚憎水珍珠岩。
(1)本工程抗震等级为2级,抗震烈度为8度,建筑等级为1级,耐火等级为1级,建筑结构使用年限等级为3级,50年,建筑场地类别
为Ⅲ级,属Ⅱ级自重湿陷性黄土场地。
(2)基础:属梁板式筏片桩承台箱形基础,“ ”字形底宽为37m,长为82.15m,底板一般厚60cm,承台高度分别为1.8m、1.50m,为了减少收缩和温度应力,在操作技术上必须采取有效的措施,防止砼产生表面和收缩裂缝。另在主楼底板面上的剪力墙下布有承台梁,其断面为
0.92m×0.8m,0.75m×1.80m,1m×1.80m。裙房基础梁断面为1m×1.5m,
0.8mm×1.6mm板底砼垫层厚150mm,上面有卷材防水层,在其上有50mm
桩长为35m,桩径D=600mm,共256根,采用钻孔混凝土灌浇桩。地下室内外墙厚分别为350、300mm,顶板厚裙厚200mm;主楼板
(3)地面上主体结构:
130mm,另在每层顶均设有框架梁连梁,其框架断面为350×750,350
×700,350×1000,350×800,连梁断面分别为:350×750,350×600,
250×500,350×500,350×400,350×550,另在主楼八层、十二层、十六层、二十层、二十四层顶D~E轴间均设钢筋混凝土休息平台。
1)桩:试桩为C35,工程结构桩和锚桩为C30。
2)垫层和保护层:C15。
3)构造柱、过梁为C20。
4)基础砼为:C35,主楼:
1、)基础顶~四层顶柱、剪力墙为C55;梁板为C45;
2、)5层至10层顶柱、剪力墙为C50;梁板为C45;
3、)十一层~十四层顶柱、剪力墙为C45;梁板为C40;
4、)十五层~十九层顶柱、剪力墙、梁、板为C40;
5、)二十层~二十五层顶柱、剪力墙、梁板为C35;
6、)二十六层以上柱、剪力墙、梁板均为C30;裙房:
1、)基础顶~二层顶柱、剪力墙、梁板为C40;
2、)三层以上柱、剪力墙、梁板为C35。
4、设备:有上下水、消防、卫生暖气、通风、煤气、通讯、照明、电控、电视、电梯等。
5、本工程施工特点:本工程施工现场狭窄,但根据甲方招标文件要求,所有土方不考虑
外运,现场留足地下室回填土。所以,土方开挖后堆置土方,所占面积较大,使本来狭窄的场地,更变得相对狭小,我单位将会同建设单位共
同洽商考虑开挖土方堆置事项。我单位初步建议在拟建裙房北侧,可适
量堆置部分土方该工程地下一层,地面上28层,局部塔楼为两层,建筑面积为38170m2,该工程计划工天为630个日历天,因为需跨两个年度春节假期,实际有效施工时间只有550天,工期要求比较紧张,主体结构施工时,模板种类多,地面上标准层墙框架柱均采用定型模数组合式钢大模板施工。
梁模板采用12胶合竹模板和50mm×1000mm方木组合配置成定尺两人可抬的梁模进行组装,楼梯采用木搁栅模板及可调式钢顶撑进行组装加固。
所有混凝土均采用商品砼进行泵送浇筑。钢筋接头:竖向暗柱钢筋接头采用电渣压力焊,水平向钢筋接头,
凡直径大于Ф12mm的,采用闪光对焊接头,或局部采用电弧搭接焊接头。
≥25HRB335(Ф)及HRB400级钢筋采用墩粗直螺纹连接。测量采用以内控为主,外控为辅,使用激光经纬仪。脚手架:采用钢管扣件双排多立杆脚手架及悬挑或钢管脚手架。安全网:主体结构和外装修施工,每隔3层在外墙设外排安全网,
按进度上升或向下敷设,地面上设一层5米宽,外高里低的小孔安全网。主体结构完成6层,折模后,及时安装施工外用电梯。
(1)本工程处于西安市经济技术**区,位于西安市北郊**路东**
号,北靠长庆石油西安基地,南临凤城三路(东临规划路),西与第二长
途电信大楼相望,在西北石油管道局住宅大院内。主要出入口:南是东
西向规划路至西和**路相交,北通过西北石油管道局住宅大楼,往西到
**路,场内因受场地窄小所限,不构环形造路,但可通过建筑西侧的场地构造砼施工道路,进行出入。
(2)工程地质条件:场地在陕西关中渭河盆地二阶地以下南平原区,南有武关、北有萧
(1)我单位将积极完善施工合同、开工报告、图纸会审、前期分项工程(土方和桩)交接手续等工作。
(2)施工前建设单位虽然已做好三通一平工作,但临时用电、用水、
道路等应继续完善,适应施工需要。施工车辆通过**路、规划路可直通
(3)施工用大型机械:塔吊、混凝土泵和搅拌站。小型加工机械:墩头机、直螺纹机、高压油泵、对焊机、钢筋切断
机、弯曲机、木工用园盘锯、平刨机、电焊机等等应进场安装试转正常,有关操作规程、规章制度均挂牌标示。
(4)劳动力:模板工、钢筋工、砼工、电工、电焊工、机操工均落实到位。
(5)现场临时设备:办公、生活用房以及生产用房、仓库、围墙、工棚、搅拌站等均已准备就绪,并进一步完善到位。
8、对建设单位的要求:
要求建设单位提供工程施工图8套、设计批文、工程地质勘察报告
1份,办理建筑执照、开工报告及有关土方和桩基等分包单位交接手续和有关技术资料。
9、主要工程量见下表:
聚乙烯橡胶共混防水卷材
240厚砌体(实心砖)
200厚砌块(空心砖)
10、工程总价约6000万元
11、总耗工160314日(包括水、电安装用工)
12、主要材料用量:水泥:9000吨木材:860m3钢材:3330吨
1、施工阶段的划分:根据本工程的特点,结构工程分为三个阶段施工。第一阶段为土方开挖和工程结构钻孔砼灌注桩施工。第二阶段为基础及地下室施工。第三阶段为地面上主体结构施工。
2、施工分段与主体交叉平行流水作业:第一段:先土方开挖,后进行工程结构钻孔砼灌注桩施工。第二段:基础及地下室施工。先施工地下室梁板式筏片桩承台板下的砼垫层、卷材防水层、细石
混凝土保护层,最后施工地下室主体结构工程。其中先进行土坡保护,坑内四周边设水沟集水井、坑上地面四周边
第五段:室内外装修施工。第六段:设备在主体结构施工期间预留预埋,其中插入部分设备安
装,主体封顶后,进行设备安装调试。为了加快工程施工进度,上述六个施工段,尽可能相互衔接,平行
(1)当桩基工程进行桩的承载力检测后,放线定位、定标高进行复
查检测,根据已知周围水准高程后,引测到在建场地四角,放水准转点。另在地面上定出各轴线的轴线桩,并把轴线引测到坑边四周,设立龙门桩和龙门板,最后再投到桩承台上用红三角标识。同时进行地面上筑挡水土堤,地下坑底局部落深基坑处挖土,浇垫层、砌砖模,当地面上完成三层拆模后,地下室经验收签证后,便可插入地下室内装修及外墙侧面防水保温层回填土施工,同时裙房基础进行开挖,各工序和主楼主体平行穿插进行施工。
每次结构验收后,就可以插入二次砌体及室内装修。当地下室主体结构办完验收签证后,就可以投入地下室外墙侧面防
当主体结构封顶后经验收签证后,就可以进行屋面卷材保温施工。同时开始外墙贴面。室内:由上而下(或由下而上),进行砌体工程和外墙内保温、内粉、安装门窗、贴面等,最后做楼地面。
期间水电、通风、暖气、消防等各种密切配合,在结构施工阶段先
3、分部分项施工方法:
15M,进入室内长度为16M,向上为93M),管径为150MM,管壁要厚,因地下室为防水砼施工,尤其底板属大体积混凝土施工,应采用带布料杆的泵车布料,臂长为30M,(布料不能覆盖处,采用料斗装料人工布)。
竖向:暗柱钢筋直径为14mm及以上者,一律采用墩粗直螺纹接头
(采用墩头机LD800 1台,套丝机TS40 1台,B6.0型高压油泵1台,其加工地点在钢筋加工棚内)。
墙中钢筋直径为14mm及以下竖向和水平向的钢筋,按设计要求采用绑扎接头,接头位置应错开,在同一截面内钢筋接头数不大于50%。墙中竖向暗柱钢筋接头除地下室和底层塔楼一层一个接头外,其余
板和梁钢筋,凡直径>Ф12mm以上者,采用闪光对焊。当承台梁
和板钢筋采用Ⅲ级,直径≥25mm(28mm),钢筋接头采用预热闪光对焊,其焊机必须采用100KVA容量,钢筋端面必须平整。其余在梁板中的水平向钢筋接头,凡直径大于≥14mm以上,宜采用连续闪光对焊接头。其余采用绑扎接头。
A、地下室施工时:桩承台板外模及承台梁模板采用多层板和50×
100木方进行配置组合,落深处采用砖模其支承支撑采用Ф48×3.5mm钢管扣件进行支撑(承)加固。
C、墙模板:采用组合定型大钢模板或采用覆面木胶板与
50mm×100mm方木为面板,支承支撑采用Ф48×3.5mm钢管扣件。
D、楼梯可采用组合小钢模板或覆面木胶合板加50×100木枋配制组合,支承采用50mm×100mm方木,支撑采用Ф48×3.5mm钢管。而楼梯外帮板,踏步板采用25mm厚木板。
E、梁、顶板模:采用覆面木胶合板与50mm×100mm方木组成的木搁栅模板,支承支撑采用Ф48×3.5mm钢管扣件满堂脚手架。
F、框架柱模采用覆面木胶合板和50mm×100mm木方加Ф14对拉钢
螺杆进行组合,加固采用Ф48×3.5mm钢管扣件进行加固。
(二)±0.00m以上主体结构模板:
A、墙模板采用定形模数式组合钢模板或多层竹胶板进行配置组合,楼板、楼梯、梁等模板和支承支撑均同地下室。
B、框架柱使用模板同地下室。
(2)梁底、顶板、楼梯模板配备三套,支承采用50mm×100mm方木,支撑采用Ф48×3.5mm钢管扣件,满堂脚手架。
(3)梁帮模及楼梯帮模配备两套。
(三)电梯井内外模采用定型模楼组合式大钢模板或定型木模板,
1#、2#电梯因无隔墙,根据井筒尺寸进行配置,3#电梯单独配置不宜采用筒子模板。但安装内模时,必须制作安装大模板的木工作台(3个,每个长、宽方向尺寸,应比井的四周围内尺寸小25mm。但相邻处应间隔<
10mm=.支模前,先行放入井端内好可伸拉的支承钢管上。模板各备用一套。
(4)装修工程:室内门框可由下往上安装,窗框应自上而下安装,楼梯应自上而下
粉刷,砌体工程先行于装修前完成。
架或外挑架。(固定点是预先施工用的墙、梁螺栓孔或预埋件),随施工进度要求,采用塔吊或人工升降就位固定。
(6)大型机械使用与安排
1、塔吊2台:必须在地下室主体结构施工前安装好。
2、双笼人货外用电梯1台:在地面上主体结构完成6层,拆模后安
3、混凝土搅拌机2台,混凝土500公升搅拌机一台,混凝土固定泵
一台(最后附有布料杆的泵车),泵管Ф150mm、200m,必须在地下室主体结构施工前安装好。
具体布置位置,详见施工平面布置图和垂直运输方案。
由总承包单位组织3支队伍,分别完成主体结构工程,内外装修工程,卷材防水屋工程,设备安装工程。
5、各项主要指标控制要求:
(2)搞好安全生产,避免发生重大伤亡事故,一般事故频率不超过
(3)合理组织劳动力,控制各阶段的工期要求,达到或不超过劳动定额。单方用工控制在4.3工日/平方米以内(按定额为4.61工日/平方米)。
(4)要求工程成本降低率为5%。
(6)施工工期按合同工期提前10天完成。
6、采用新工艺、新技术、新材料:
(二)新型模板应用:本工程剪力墙、框架柱模板采用模数式大钢模板。(模板根据一定的模数进行设计,用骨架和面板组成各种不同尺寸的模板,现场可以按剪力墙面尺寸进行组合成大模板。其特点是能适应不同建筑结构的要求,提高模板的利用率。)
(三)建筑节能方面应用技术:(1)外墙采用节能门窗:单框双玻璃铝合金门窗,空气间层9mm厚。住户采用三防门,传热系数≤
2.70W/m2K。(2)外围护结构节能:住宅外墙和办公室部分外墙在200厚非承重空心砖或钢筋混凝土墙内侧贴50厚ASA板进行保温。屋面保温层采用120mm厚憎水膨胀珍珠岩块。底层楼层地面加1400mm厚炉渣垫层。
(四)新型建筑防水应用技术:(1)本工程的地下室承台底板下和外墙外侧面、屋面防水、均采用了高聚物(高分子)改性沥青类防水卷材SBS作防水层。这是公认的改性效果显著的防水卷材:使卷材在低温
但扩大了卷材的应用温度范围,同时也提高了沥青的强度,延度和卷材
的耐老化的能力,延长了使用寿命。
(五)计算机应用及管理技术:本工程采用计算机在施工管理方面应用于工程网络计划编制。
(2)本工程采用其他的新工艺如下:
②钢筋焊接接头:采用闪光对焊和电弧焊接头。
③测量放线:采用内控为主,使用激光经纬仪;外控为辅,采用J2经纬仪。
⑥模板的隔离剂,采用JS系列(江苏省苏州混凝土水泥制品研究院研制,镇江金星化工厂生产)。
⑦地下室桩头防水采用赛柏斯防水涂料XYPEY。
7、与建设单位和监理的配合:
(1)根据现场实际情况,了解施工区域及边线位置关系,合理规划
施工平面图,落实好施工、安全、保卫、交通、卫生、市容、砼搅拌浇
筑、噪音处理等措施,制订详细文明工地方案,请建设单位监理审定后实施。
(2)本工程对其中重要的分项分部施工方案或专业性要求高的施工工艺,如地下室防水及外墙附加防水层和后浇带施工;外墙内侧采用轻质ASA,聚苯板保温层施工;屋面采用憎水珍珠岩块和改性沥青防水卷材SBS施工;外墙贴面施工等等,外墙主体结构和装修脚手架采用附墙国力牌框架(导轨)式多功能爬架脚手架或悬挑封闭式钢管脚手架。
(3)严格履行验收、签证、监督制度。若建设单位提出了需对材料、设备、隐蔽内容等要求复验、应积极配合,直至达到放心和达标为止。
(4)积极配合设计、建设单位、市质检等部门来工地检查指导工作,提供一切便利条件,遇有问题及时解决。
(5)积极配合好甲供设备材料的进场、堆放、保管、复测查验、接收质保书和出厂合格证。
(6)凡本公司采购的主要材料,如型钢、装饰材料、设备等在质量,价格上应征得建设单位意见,达到共同把关。
(7)每月提供生产进度报表,形象进度计划给建设单位,便于对整个工程在施工工期、进料时间、资金计划方面的调整。
(8)本工程交付使用后三个月内,由本公司组织进行质量回访。回访出有关施工质量问题,由本公司负责返修。本工程交付使用,按《建设工程质量管理条件》第279号文规定的保修期及甲乙双方签订的保修
期文本负责保修,凡属质量问题,本公司承担全部修理费用。
(9)施工单位应于合同签订后7天内书面通报施工组织机构及公司在该工程上的项目负责人。
(10)施工单位按合同要求的时间开工,并于开工前书面报告施工准备情况,获得监理方认可后可开工(办理开工报告手续)。如有困难应提前5天向监理方申述,获准后办理延期开工手续。
(11)开工前应将正式施工组织设计,报送监理方审定。
(12)图纸会审,应在开工前,施工单位应组织有关人员熟悉施工图,先行进行内部会审,把有疑问不清有误和不符合设计要求的意见汇总。然后配合监理方在开工前一星期,由设计、施工、建设单位、监理方进行图纸会审。先由设计单位交底,而后再行图纸会审(提问和回答),做好会审纪要工作。
(13)施工用各类建材样品,均需向监理方报送样品,材质证明和有关技术资料,经监理方审核批准后方可采购使用。就变更用材料,需事前征得同意。
(14)施工单位如使用专业分包队伍,须在分包合同签订前,按监理方要求,提供分包单位的有关资料,征得监理方同意后,方可使用。
(15)各类材料配合比,钢筋焊接及其他材料,新技术、新工艺的使用于事前报送试配、试焊结果及有关资料,经监理方审核后方可使用投产。
(16)监理方对每道工序的操作及质量,进行旁站监理,施工单位
于每道工序前必须做好施工技术交底,每一工序完成后必须做好质量自
检并将自检资料送监理方,经监理方复查认可签证后,方可进行下一道
(17)隐蔽工程完成后,施工单位应在自检合格的基础上,提前24小时书面通知工程监理方(如有必要还得通知市质检站)。与此同时,将隐蔽自检资料交监理审验。
(18)监理方对某些质量有疑问,而要求施工单位复测时,施工单位应予积极配合。并对检测仪器的使用提供方便。若发生费用和有关责任时,则按施工合同规定的原则处理。
(19)施工单位应及时向监理方报送分部分项工程质量自检资料和砼、砂浆强度报告。
(20)现场出现质量事故后,施工单位应及时报告监理方,并严格按照共同方案进行处理,任何质量缺陷均不得隐瞒监理方,自行处理。
(21)监理工程部对工程质量有否决权。
(22)施工单位应遵守执行监理方的指令,如有异议时,应在三日内提出书面申述,否则监理方可不承认该部分工作量。
(23)工程量的确定:施工单位按约定的时间,向监理方提交已完工程量的报告。监理方
接到报告后7天内按图纸核实已完工程量,并在计量前24小时通知施工单位,施工单位为工程量计量提供便利条件并派人员参加。施工单位收到通知后,不参加计量,计量结果有效,作为工程价款支付的依据。
监理方收到施工单位报告后7天内未进行计量,从第8天起DB13/T 5056-2019标准下载,施工单位报告中开列的工程量即视为被确认,作为工程价款支付的依据。监理方不按约定时间通知施工单位,致使施工单位未能参加计量,计量结
(24)合同鉴定一个月后,施工单位应向监理方报送施工图预算。
(25)每月完成工程量及工程进度款的申报,须按合同规定的时间进行。逾期不进行申报的,监理方不再受理。监理工程部收到报告后,7天后完成验收复计工作,签发付款凭证,由业主按合同规定的时间支付。
(26)现场出现安全事故,施工单位应按规定上报。监理方接到报告后,将协助施工单位做好事故的善后处理工作。
(27)施工单位于工程全部完成后,经过认真自检、认为符合交工条件时,可向监理方提交验收申请,监理方复验认可后,报业主组织正式竣工验收。
(28)施工单位申请竣工验收前7天XFT 3003-2020 火灾调查车装备通用技术要求.pdf,应将竣工验收技术资料交监理方审查。